: A compact, single-unit version where the master compass (MKM 022) drives repeater compasses directly without an external control box.
This section provides block diagrams and wiring schematics. The CMZ 700 system typically comprises: yokogawa gyro compass cmz 700 user manual
CDU blank but master unit LED on
: Includes a maintenance mode with over 40 command codes for simulated signal output, error log display, and resetting gyrosphere runtime. : A compact, single-unit version where the master
Gyrocompasses are delicate. The manual specifies that the master compass must be removed every 5,000 operational hours for bearing replacement and oil change. Furthermore, it details how to clean the optical sensors without scratching them. A major warning in this section: Use of compressed air inside the gyro sphere voids the warranty. : A compact